Article: 120 — Load Calculations
Part: Part IX — Mobile and Manufactured Homes
Section: 120.140(B), 120.140(C)
Format: Quick Hit
We've already built most of the mobile-home load calculation.
Now it's time for one specific load that gets its own dedicated table:
🍳 The freestanding range
Section 120.140(B) directs us to Table 120.140(B) to determine the calculated load for a freestanding range.
And then, just before the mobile-home calculation wraps up, 120.140(C) gives us one last shortcut that takes us all the way back to 120.82.
Freestanding ranges aren't simply added at their full nameplate rating.
Instead, Table 120.140(B) provides a calculated load based on the range's nameplate rating.
And there's an interesting twist:
The first tier uses a percentage, while the higher tiers use specific flat VA values.
For a freestanding range with a nameplate rating of 10,000 watts or less:
➡️ 80% of the rating
For example:
8,000 W × 80% = 6,400 VA
So an 8,000-watt range contributes:
➡️ 6,400 VA
to the calculated mobile-home load.
For a range rated over 10,000 watts but not over 12,500 watts:
➡️ 8,000 VA
Notice that we're no longer simply multiplying the nameplate rating by a percentage.
The table gives us a flat calculated value.
➡️ 8,400 VA
➡️ 8,800 VA
➡️ 9,200 VA
➡️ 9,600 VA
➡️ 10,000 VA
Freestanding Range Nameplate
Calculated Load
0–10,000 W
80% of rating
Over 10,000–12,500 W
8,000 VA
Over 12,500–13,500 W
8,400 VA
Over 13,500–14,500 W
8,800 VA
Over 14,500–15,500 W
9,200 VA
Over 15,500–16,500 W
9,600 VA
Over 16,500–17,500 W
10,000 VA
Most of the demand-factor tables we've encountered throughout Article 120 have followed a familiar pattern:
Connected load × demand factor = calculated load
Table 120.140(B) changes things up.
For the higher range ratings, the table gives us flat VA values instead of simply applying a percentage.
That's an important detail because you don't want to look at a 12,000-watt range and automatically try to calculate 80% of 12,000.
The table tells you the calculated value.
A mobile home has a freestanding range with a nameplate rating of:
8,000 watts
The rating falls within the 0–10,000 W tier.
Therefore:
8,000 W × 80% = 6,400 VA
6,400 VA
That's the number that gets carried into the overall mobile-home load calculation.
After working through the mobile-home calculation, there's another option worth knowing.
Section 120.140(C) permits the use of the 120.82 optional dwelling-unit method for the lighting and appliance load portion.
If you've followed this series from the beginning, you've already seen 120.82.
We spent five episodes breaking down that optional dwelling method.
Now it comes back around in the mobile-home calculation.
Earlier in the series:
120.82
⬇️
Optional dwelling-unit method
⬇️
General loads + heating/AC + EVSE
⬇️
Now:
120.140(C)
⬇️
The 120.82 method can be used for the applicable lighting and appliance load portion of the mobile-home calculation.
Everything connects.
When you see Table 120.140(B), think:
🍳 Freestanding range
📊 Dedicated range load table
⚡ 0–10,000 W → 80%
➡️ Higher ratings use specific flat VA values
And when you see 120.140(C):
🔄 Think 120.82 optional dwelling-unit method
That's the shortcut that brings the series almost full circle.
Per Table 120.140(B), a freestanding range has a nameplate rating of 8,000 watts.
What is the calculated "use" value?
A) 8,000 VA flat
B) 6,400 VA (80% of rating)
C) 8,400 VA
D) 4,000 VA
B) 6,400 VA (80% of rating)
The 8,000-watt range falls within the 0–10,000 W tier.
So:
8,000 W × 80% = 6,400 VA
Continue the Article 120 Quick Hits:
🌐 www.JoshTheSparky.com/quick-hits
Test yourself with Brain Busters:
🧠 www.JoshTheSparky.com/brain-busters
Answer the Question of the Week:
❓ www.JoshTheSparky.com/question-of-the-week
Read Sparky's Journal:
📓 www.JoshTheSparky.com/sparkys-journal
Catch the latest Sparky Weekly:
📰 www.JoshTheSparky.com/sparky-weekly
View Sources & References:
📚 www.JoshTheSparky.com/Sources
Primary: Article 120, 120.140(B)
Related: Table 120.140(B) — Freestanding Range Load
Related: 120.140(C) — Optional Dwelling-Unit Method
Related: 120.82 — Optional Dwelling-Unit Calculation Method
Article 120 — Load Calcs Won't Kill You
🏠 Part IX — Mobile and Manufactured Homes
Episode 46: Mobile Homes: A Whole Different Calculation System
Episode 47: Mobile Homes: Everything Else Gets Added On
Episode 48: The Freestanding Range Table + One Last Shortcut
We've now covered:
🏠 The mobile-home calculation system
➕ The additional mobile-home loads
🍳 The freestanding range table
🔄 The 120.82 shortcut
But we're not finished yet.
One final section remains.
Next up: mobile-home parks and the final demand-factor rules that bring Article 120 to its conclusion.
One last table.
One last calculation.
One last Quick Hit.
⚡ Let's finish Article 120.