Episode 18 — 120.55 Electric Cooking Appliances
Ranges, ovens, cooktops, and other household cooking appliances don't simply get thrown into a basic nameplate calculation.
For qualifying cooking equipment, 120.55 provides a specific calculation method using Table 120.55.
Let's start with the foundation.
The provisions apply to household electric cooking appliances such as:
Household electric ranges
Wall-mounted ovens
Counter-mounted cooking units
Other household cooking appliances
when they are rated over 1¾ kW.
Qualifying cooking appliances can be calculated using:
Rather than simply using each appliance's individual nameplate rating at full value.
For this calculation:
No additional power-factor conversion is needed for the calculation method described here.
Don't overcomplicate it.
If the appliance is rated in kW, that value can be treated as the corresponding kVA value for this calculation.
The provisions aren't limited strictly to residential kitchens.
The cooking-appliance calculation can also apply to cooking appliances used in instructional programs.
A school kitchen used for a home-economics or similar instructional program may have cooking appliances that fall under this provision.
Here's another phase-distribution rule to remember.
When there are two or more single-phase cooking appliances supplied by a 3-phase, 4-wire feeder or service, the calculated load is based on:
The calculation accounts for how the single-phase cooking appliances are distributed across the three phases.
So don't automatically assume:
Add every appliance together
Instead, identify the maximum number connected between any two phases, then apply the required multiplier.
A) Only appliances rated exactly 1¾ kW
B) Any household cooking appliance rated MORE than 1¾ kW
C) Only ranges, never ovens or cooktops
D) Only commercial cooking equipment
👇 What's your answer?
The provision covers qualifying household electric cooking appliances rated over 1¾ kW, including ranges, wall-mounted ovens, counter-mounted cooking units, and other household cooking appliances covered by the section.
Over 1¾ kW
↓
Use Table 120.55
↓
kW = kVA for this calculation
And remember the special 3-phase, 4-wire rule when multiple single-phase cooking appliances are involved.
The actual Column A, Column B, and Column C demand-factor values of Table 120.55 are not reproduced here because the table itself was not available in the source material used for this Quick Hit.
This episode therefore explains the methodology and requirements described in the available material rather than supplying unverified demand-factor percentages.
For the exact applicable demand-factor values, consult the official NEC and the complete Table 120.55.
Continue exploring the JoshTheSparky Quick Hits library.
Test what you know with the JoshTheSparky Brain Busters.
Take the latest JoshTheSparky Question of the Week.
Go deeper into electrical thoughts, lessons, discoveries, and experiences in Sparky's Journal.
Follow the latest progress, discoveries, projects, and industry updates in Sparky Weekly.
Review the references and resources used throughout JoshTheSparky.com in the JoshTheSparky Sources library.
← Back to Article 120 Quick Hits
→ Episode 19 — Cooking Appliance Demand Factors
This Quick Hit is an educational explanation based on the author's understanding of the NEC. It is not a substitute for the official NEC, applicable local amendments, manufacturer instructions, or the determination of the Authority Having Jurisdiction (AHJ).
Always verify the requirements applicable to your specific installation.